Technical parameters:
Sample form: 96 holes or bars
Linear range: 100—2000K relative light units
Sensitivity: TSH analyzing sensitivity ≤0.01uIU/ml
Interference between adjacent holes: Less than 1×10-6
Repeatability: CV<2%
Detecting speed: 96 holes in 3 minutes (96 holes sample test)
Time of measurement: 0.1-6s/hole
Barcode identification: Barcode is used for the parameters of all matching reagent in order to facilitate using, handling and storage by the end user, and to reduce artificial error as well.
Communication port: RS232 serial port or USB high speed port.
Operation environment: 110-250VAC,50-60Hz
Size: 644mmX440mmX278mm
Weight: 15KG
Chemiluminescence immunoassay has many applications in laboratory medicine, including tumor markers, cardiac markers, thyroid function, insulin and C-peptides and diabetes, infectious diseases, bone metabolism, cytokines, hormones, growth hormone systems, anemia diagnosis and differential diagnosis, allergic reactions, and therapeutic drug concentration monitoring.
Technical parameters:
Sample form: 96 holes or bars
Linear range: 100—2000K relative light units
Sensitivity: TSH analyzing sensitivity ≤0.01uIU/ml
Interference between adjacent holes: Less than 1×10-6
Repeatability: CV<2%
Detecting speed: 96 holes in 3 minutes (96 holes sample test)
Time of measurement: 0.1-6s/hole
Barcode identification: Barcode is used for the parameters of all matching reagent in order to facilitate using, handling and storage by the end user, and to reduce artificial error as well.
Communication port: RS232 serial port or USB high speed port.
Operation environment: 110-250VAC,50-60Hz
Size: 644mmX440mmX278mm
Weight: 15KG
• Ka pane manawa: No kāu nīnau a pau, e ho'āʻo mākou e pane i loko 24 hola
• Hoʻoholo maikaʻi: E nānā i ka maikaʻi ʻelua ma mua o ka hoʻouna ʻana, inā pilikia ka maikaʻi e hāʻawi mākou i ka uku.
• Ma ka manawa hoʻouna: E hoʻouna ʻia kāu kauoha i ka pau ʻana o ka mana maikaʻi
• Ma ka manawa ma hope o nā lawelawe kūʻai: E pane ʻia kekahi nīnau ma hope o ke kūʻai aku 24 hola.
• Ma mua o 13 makahiki 'ike o ka mea hana laau lapaau
• Hāʻawi i nā lako lapaʻau maikaʻi loa
• 'Oihana kuai a me technician hui kuleana no kela a me keia o oukou ninau, a pololei i ke kiko.
• Nā ʻōlelo aʻoaʻo huahana like ʻole no kāu pono like ʻole a me nā kālā like ʻole.
Pono e hoʻopau ʻia nā huahana a pau 4 hōʻoia i ka hana holoʻokoʻa:
1. Nānā haʻawina
2. I ka hooponopono ana
3. Nānā hope ma mua o ka hoʻopaʻa ʻana
4. E nānā ka mana maikaʻi ma mua o ka hoʻouna ʻana
Q:How to place order of B016 Chemiluminescence immunoassay analyzer CLIA analyzer?
A:
• Hoʻopaʻa mua mākou i nā kikoʻī huahana a laila hoʻouna i ka Proforma Invoice,
• Uku oe ia makou ma o T/T, Western Union a i ʻole MoneyGram,
• Ma hope o ka hōʻoia ʻana i kāu uku a laila e hoʻouna i ka huahana iā ʻoe i ka pau ʻana o ka hana.
Q: He aha kāu palapala hoʻokō?
A:
• No ka hapanui o nā huahana ka palapala hoʻokō no 12 mahina, kekahi mau huahana a mākou e hoʻolako ai 18 mahina palapala hoʻokō.
• No ka'ōpū'ōpū ultrasound mīkini hāʻawi mākou 12 mahina palapala hoʻokō.
Q: He aha kāu manawa hoʻouna?
A:
• ʻO ka maʻamau 5 nā lā hana inā loaʻa nā waiwai. Iloko 10 nā lā hana inā pono ka huahana,
• And also the delivery time depends on quantity.For B016 Chemiluminescence immunoassay analyzer CLIA analyzer the delivery time is 10 nā lā hana.
Q: Pehea e hoʻouna ai i ka huahana?
A:
• ʻO ke ala hoʻouna maʻamau e hilinaʻi ma kāu nui, huina CBM a me ke kaumaha.
• Loaʻa iā mākou kā mākou hui moku ponoʻī e hāʻawi i ka uku hoʻouna maikaʻi loa
Inā he mau pilikia kāu e pili ana mīkini hale hana, a i ʻole makemake e ʻike i nā kikoʻī hou aku e pili ana i nā lako Vet, mīkini hale hana, Lako Halemai, etc. Welina mai e hoʻokaʻaʻike mai iā mākou!